| Building
Area |
278,330
sq. ft. of Class A office space on seven floors
situated on 2.18 acres. |
| Amenities |
Four-level,
covered, self-parking garage, on-site food service,
full service dry cleaning, walking distance to shops,
banks and restaurants, 24-hour manned security service,
adjacent to Sheraton and Ridgeway Shopping Plaza |
| Accessability |
Access
to Exits 7 & 8 off I-95 and Exits 34 & 35
off the Merritt Parkway. (Metro
North New Haven Line Train Schedule) Click
here for a local and regional map. |
| Ownership |
Stamford
Square Associates |
| Management |
Albert
B. Ashforth, Inc. provides an experienced, on-site
property management team. |
| Major
Tenants |
General
Electric, KPMG, IBM |
| Year
Built |
Constructed
in 1980. Designed by the architectural firm of
Emery Roth
& Sons. Developed by Ashforth Properties, Inc. |
| Parking |
Four-level,
757-car self-parking garage with direct elevator
access to main lobby and offices. |
|
| Security
& Access |
Secured
24 hours a day, seven days a week, uniformed security
posted in lobby and “D Level” in parking
garage; card access system for all admittance to
offices. |
| Construction |
Post
tension, steel and concrete with marble and tinted
double glazed glass |
| Ceiling
Heights |
A
typical suspended finished ceiling dimension is 8’ 4”.
Slab to slab ceiling height is 10’ 2”.
Clear to steel ceiling height is 10’ 2”. |
| HVAC |
Heating
provided by a water source heat pump system. Heating
system is capable of maintaining inside space conditions
of more than 68 degrees F when outside air temperature
is equal to or more than 0 degrees F at 30% humidity.
Cooling System is capable of maintaining inside
space conditions of 78 degrees F dry bulb and 50%
relative humidity when outside air temperature
is less than 95 degrees F dry bulb and 85 degrees
F wet bulb. |
| Electricity |
Numerous
480-volt, three-phase power through a buss duct system
is available at two locations on each floor. |
| Technology |
Entire
building wired with state-of-the-art, high-speed
voice, data and video communications services,
as well as redundant capabilities for added reliability. |
| Fire
& Life Safety |
Fully
sprinklered and compartmentalized; fully integrated
fire alarm system including smoke detectors, thermal
detectors and smoke evacuation; Automatic External
Defibrillator (AED) at concierge |
| Elevators |
Six
high-speed elevators and 1 freight elevator |
|