| Location |
Located
at the confluence of the four major roads to downtown Stamford
(Long Ridge Road, High Ridge Road, Bedford Street, and Summer
Street), half way between downtown Stamford and the Merritt
Parkway. |
| Building
Area |
278,330
sq. ft. of Class A office space on seven floors situated
on 2.18 acres. |
| Amenities |
Four-level,
covered, self-parking garage, on-site food service, full service
dry cleaning, walking distance to shops, banks and restaurants,
24-hour manned security service, adjacent to Sheraton and
Ridgeway Shopping Plaza |
| Accessability |
Access
to Exits 7 & 8 off I-95 and Exits 34 & 35 off the
Merritt Parkway. (Metro
North New Haven Line Train Schedule) Click
here for a local and regional map. |
| Ownership |
Stamford
Square Associates |
| Management |
Albert
B. Ashforth, Inc. provides an experienced, on-site property
management team. |
| Major
Tenants |
General
Electric, KPMG, IBM |
| Year
Built |
Constructed
in 1980. Designed by the architectural firm of Emery Roth
& Sons. Developed by Ashforth Properties, Inc. |
| Parking |
Four-level,
757-car self-parking garage with direct elevator access to
main lobby and offices. |
|
| Security
& Access |
Secured
24 hours a day, seven days a week, uniformed security posted
in lobby and “D Level” in parking garage; card
access system for all admittance to offices. |
| Construction |
Post
tension, steel and concrete with marble and tinted double
glazed glass |
| Ceiling
Heights |
A
typical suspended finished ceiling dimension is 8’ 4”.
Slab to slab ceiling height is 10’ 2”. Clear to
steel ceiling height is 10’ 2”. |
| HVAC |
Heating
provided by a water source heat pump system. Heating system
is capable of maintaining inside space conditions of more
than 68 degrees F when outside air temperature is equal
to or more than 0 degrees F at 30% humidity. Cooling System
is capable of maintaining inside space conditions of 78
degrees F dry bulb and 50% relative humidity when outside
air temperature is less than 95 degrees F dry bulb and 85
degrees F wet bulb. |
| Electricity |
Numerous
480-volt, three-phase power through a buss duct system is
available at two locations on each floor. |
| Technology |
Entire
building wired with state-of-the-art, high-speed voice,
data and video communications services, as well as redundant
capabilities for added reliability. |
| Fire
& Life Safety |
Fully
sprinklered and compartmentalized; fully integrated fire
alarm system including smoke detectors, thermal detectors
and smoke evacuation; Automatic External Defibrillator (AED)
at concierge |
| Elevators |
Six
high-speed elevators and 1 freight elevator |
|